2.2 Kw 3kw 200kw 250 Kw 400kw Soft Starter with Built-In Bypass Protection and Monitoring Short-Circuit

Brand Name : Anchorwill

Model Number : Ck60

Certification : 3C

Place of Origin : China

MOQ : 1

Payment Terms : L/C, T/T

Delivery Time : 1 - 10

Packaging Details : Packing in wooden cases for export

Product name : Ball Mill Soft Starter

Applicable motor type : Squirrel-cage three-phase asynchronous motors

Motor power : 11A……1260A(5.5~630kW)

Adjustable stopping time : 0~120s adjustable

Display Unit : LCD display

Protection and monitoring : Short-circuit, over-voltage, overload, under-voltage, phase loss, over-current, temperature protection

Integrated communication protocols : Standard Modbus protocol, 1 channel

Contact Now

Ball Mill Soft Starter Ck60 Built-In Bypass Soft Starter
product description

By limiting the starting current and starting torque, the soft starter is able to reliably prevent mechanical shock and grid voltage drop during starting. By controlling the conduction angle of the thyristor, the motor starting voltage is reduced and raised to the rated voltage within the set starting time. With this stepless control of the motor voltage, the motor can be regulated according to the load characteristics of the driven machine, gently accelerating the mechanical equipment.

This significantly improves the operating performance of mechanical equipment, reduces maintenance costs and extends service life.

Widely used in water supply pumps, ventilation systems, air-conditioning refrigeration station circulating pumps in water conservancy, mines, factories, high-rise buildings, large shopping malls and other places,

Fire-fighting and sprinkler pump control, etc.

Item Project Description
Applicable standards GB14048.6-2016(IEC947-4-2)
Applicable motor type Squirrel-cage three-phase asynchronous motors
Motor power 11A……1260A(5.5~630kW)
Control Voltage AC220V±15%;50Hz/60Hz;AC110V±15%
input Rated Voltage AC380V±15%;50Hz/60Hz;660V±15%
Adjustable start time 1~120s adjustable
Adjustable stopping time 0~120s adjustable
control mode 1.Ramp voltage 2.Ramp current 3.Current limit mode
I/0 Logic Inputs 3 way(X1~X3)
Analog Outputs 1 channel 4~20mA/0~10V
Relay outputs 2 relay outputs
Run command inputs Keyboard display unit given, control terminal given
RS485 communication given
Communication Integrated communication protocols Standard Modbus protocol, 1 channel
Display Unit LCD display Can display current, voltage, alarm and other motor parameters
Protection and monitoring Short-circuit, over-voltage, overload, under-voltage, phase loss, over-current, temperature protection
matrix Location Indoor, not subject to direct sunlight, no dust, corrosive, flammable gases, oil mist,
water vapor, dripping water or salt, etc.
altitude Altitude more than 1000m, the capacity should be reduced accordingly, every increase of 100m, the current is reduced.
Environmental humidity -10℃~+40℃; -40℃ or above shall be used at a reduced capacity.
Above 40℃ shall be used at reduced capacity
For every 1℃, the current shall be reduced by 2%.
Temperature Less than 95%RH, no water droplet condensation.
Vibration Less than 5 .9m/s2(0 .6g)
Storage Temperature -40℃~70℃
framework Protection class Ip20
Cooling method Radiator, natural cooling
Installation Vertical installation in cabinet

Note:
CK60 built-in bypass economic soft starter adopts two start-stop control methods: panel giving and control terminal (two-wire and three-wire) giving.
1. Two-wire control is hold signal, three-wire control is trigger signal.2.2 Kw 3kw 200kw 250 Kw 400kw Soft Starter with Built-In Bypass Protection and Monitoring Short-Circuit
2. When two-wire control is adopted, panel control is invalid.
3. When three-wire control is used, panel control is effective.
4. When panel control is adopted, X3 and COM must be kept closed.
5. External button signal should be kept >200ms to be valid, <200ms to be invalid.

2.2 Kw 3kw 200kw 250 Kw 400kw Soft Starter with Built-In Bypass Protection and Monitoring Short-Circuit

2.2 Kw 3kw 200kw 250 Kw 400kw Soft Starter with Built-In Bypass Protection and Monitoring Short-Circuit


Product Tags:

250 Kw Soft Starter

      

2.2 Kw Soft Starter

      

3kw Soft Starter

      
Best 2.2 Kw 3kw 200kw 250 Kw 400kw Soft Starter with Built-In Bypass Protection and Monitoring Short-Circuit wholesale

2.2 Kw 3kw 200kw 250 Kw 400kw Soft Starter with Built-In Bypass Protection and Monitoring Short-Circuit Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Suzhou ANCHORWILL Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0